Searching the RRID Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.

Search

Type in a keyword to search

On page 10 showing 181 ~ 200 out of 738 results
Snippet view Table view Download 738 Result(s)
Click the to add this resource to a Collection

http://www.speciation.net/Database/Instruments/Carl-Zeiss-AG/Supra-25-;i665

Field scanning electron microscope with analytical specimen chamber with choice of optional detectors and accessories. It has 5-axes motorised cartesian stage can handle multiple smaller specimens simultaneously. It can image bulky or irregular shaped specimens.

Proper citation: Zeiss: Supra 25 Field Emission Scanning Electron Microscope (RRID:SCR_020930) Copy   


https://promega.media/-/media/files/products-and-services/instruments/detection/tbs-technical-support-docs/tbs380-manual.pdf?la=en

TBS-380 Mini-Fluorometer is a dual-channel fluorometer designed for quick, easy, and accurate fluorescence measurements. When properly calibrated with a standard of known concentration, the TBS380 displays the actual concentration of the measured compound. The new Minicell adaptor design enables the user to measure compounds at a low concentration with a low assay volume (e.g. dsDNA at 1ng/mL using PicoGreen, and RNA at 1 ng/mL using RiboGreen).

Proper citation: Turner BioSystems: TBS-380 Fluorometer (RRID:SCR_020863) Copy   


https://www.yxlon.com/en/products/x-ray-and-ct-inspection-systems/yxlon-ff70-cl

X ray inspection system has been developed to enable automated analysis for flaws in semi-conductors. Flaws can be found on wafer, on substrate, in strip in sub assembly or in final device.

Proper citation: YXLON: FF70 CL X-Ray System (RRID:SCR_020908) Copy   


https://www.yxlon.com/en/products/x-ray-and-ct-inspection-systems/yxlon-cougar-evo

X-ray machine for inspection of SMT, semiconductor, and laboratory assembly applications.

Proper citation: YXLON: Cougar EVO Series X-Ray (RRID:SCR_020906) Copy   


  • RRID:SCR_020903

    This resource has 1+ mentions.

https://www.yxlon.com/en/products/x-ray-and-ct-inspection-systems/yxlon-ff20-ct

Computed tomography system for 3D inspection results at high resolution. In electronics and material science industries can use it for R&D, defect analysis, process monitoring, or CT metrology.

Proper citation: YXLON: FF20 CT System (RRID:SCR_020903) Copy   


https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/refs/heads/main/PDF/SCR_020868.pdf

UMAX PowerLook 2100XL is a scanner for graphics professionals who require high resolution and fast color scanning of any image in a small package. You can scan illustrations, newspapers, magazines, transparencies, color photos, and even x-rays, textiles, and negatives. The scanning area measures a full 12" by 17", despite the small footprint of just over 18" by 24" to fit on any desktop. The scan area can accommodate up to thirty-two 35mm slides when used with the transparency adapter. High 3.4Dmax captures fine details of shadow areas -- especially important when scanning transparencies. In addition, batch scanning increases productivity by scanning more than one image in a single pass.

Proper citation: UMAX: 2100XL Flat Bed Scanner (RRID:SCR_020868) Copy   


https://www.perkinelmer.com/product/ivis-instrument-spectrum-120v-andor-c-124262

In vivo imaging system that combines 2D optical and 3D optical tomography in one platform. The system can be used for preclinical imaging research and development best for non-invasive longitudinal monitoring of disease progression, cell trafficking and gene expression patterns in living animals.

Proper citation: Perkin Elmer:: Xenogen IVIS 100 Imaging System (RRID:SCR_020901) Copy   


https://www.yxlon.com/en/products/x-ray-and-ct-inspection-systems/yxlon-cheetah-evo

X-ray inspection system for SMT, semiconductor, and laboratory assembly applications.

Proper citation: YXLON: Cheetah EVO Series X-Ray (RRID:SCR_020902) Copy   


https://www.yxlon.com/en/products/x-ray-and-ct-inspection-systems/yxlon-ff65-cl

X ray inspection system for automatic analysis of smallest and most demanding features within 3D IC, MEMS and sensors.

Proper citation: YXLON: FF65 CL 3D X-Ray (RRID:SCR_020910) Copy   


http://www.biosurplus.com/store/models/3091-1450-microbeta-plus/

Wallac 1450 MicroBeta is a liquid scintillation counter and luminescence detector that can accommodate either 1, 2, 3, 6, or 12 detectors, each of which can count in 96- and 24- or 96- and 384-well plate formats. Samples may be counted in microplates, tubes, or on filters for added flexibility. The counter features dual photomultiplier tubes (PMT), with the first PMT set over the sample and the second located below. This method of coincidence counting provides optimal productivity for any compatible assay, including proximity and filtration assays among others.

Proper citation: Wallac: 1450 Liquid Scintillation Counter (RRID:SCR_020878) Copy   


https://www.labx.com/item/rigaku-x-stream-2000-cryogenic-crystal-cooler-system/LV40211010

Cryogenic Crystal Cooler is a self-contained apparatus designed for cooling crystals to a temperature within the range of -180C to 4C. The X-stream 2000 system takes room air, compresses it, and removes the impurities from it to produce clean, dry nitrogen. This gas is then cooled to nearly -196C, and then rewarmed to the desired temperature

Proper citation: Rigaku: X-Stream 2000 Cryo-freezing System (RRID:SCR_020911) Copy   


https://www.waters.com/waters/en_US/1525-Binary-HPLC-Pump/nav.htm?cid=534310&locale=en_US

Itegrated, high-pressure, binary HPLC pump that feature on-board pulse dampening and efficient mixing. Their pulse-free solvent flow, from analytical to semi-preparative flow rates, makes them best for use with highly sensitive detectors. Designed for use with 2 to 4.6 mm I.D. columns in routine LC and LC/MS applications, these pumps have a programmable flow-rate range of 0.00 to 10.00 mL/min in 0.01 mL increments.

Proper citation: Waters: 1525 Binary HPLC Pump (RRID:SCR_020875) Copy   


https://www.waters.com/webassets/cms/support/docs/71500023202rc.pdf

Waters 2996 PDA Detector can be used for in-vitro diagnostic testing to analyze many compounds, including diagnostic indicators and therapeutically monitored compounds. It also describes detector optics and the principles of Spectral Contrast used in the Millennium32 software for analyzing the data from the PDA detector.

Proper citation: Waters: 2996 Photodiode Array Detector (RRID:SCR_020876) Copy   


https://mobile.labwrench.com/equipment/22026/zeiss/axioplan-microscope-system

Upright microscopy imaging platform for complex research that is optimized for light transmission and extremely high contrast fluorescence imaging. This complete system comes fully configured for best performance, range and functionality.

Proper citation: Zeiss: Axioplan 2 imaginig system (RRID:SCR_020918) Copy   


https://neuroscience-a2.sites.medinfo.ufl.edu/wordpress/files/2023/11/EN_product-info_Lightsheet-Z.1_rel-2.3.pdf

Light sheet fluorescence microscope for the imaging of large cleared specimens. Lightsheet Z.1 with Clr Plan-Apochromat 20x/1.0 Corr nd=1.38 is used to perform experiments with tissue cleared by Scale medium (Hama et al, Nat Neurosci. 2011), which has a refractive index of n=1.38.

Proper citation: Zeiss: Lightsheet Z.1 Fluorescence Microscope (RRID:SCR_020919) Copy   


  • RRID:SCR_020916

https://www.bcm.edu/research/advanced-technology-core-labs/lab-listing/optical-imaging-and-vital-microscopy-core/instrumentation-technology/lsm5live

Visible confocal microscope that acquires the X dimension simultaneously on a line CCD detector while scanning only in the Y dimension. This allows users to increase the speed of image acquisition compared to traditional confocal systems. This system is equipped with two fluorescence detectors and 4 lasers lines at 405nm, 488nm, 561nm and 633nm. It is capable of scanning over 120 FPS for a large field of view.

Proper citation: Zeiss: 5-Live (RRID:SCR_020916) Copy   


https://www.gmi-inc.com/product/beckman-j2-21m-high-speed-centrifuge/

Beckman J2-21M is a high speed floor model centrifuge which features a brushless induction drive and maintenance-free system. Capable of performing at a speed of 21,000 rpm and forces up to 51,500 g, the J2-21M offers superior functionality, accuracy, and productivity. The system's microprocessor-controlled design provides quick and automatic operation. The J2-21M Centrifuge stores up to 10 programs and eliminates errors in repetitive runs. The system also offers a choice of ten dual-ramp acceleration and deceleration settings for gentle starts and quick running.

Proper citation: Beckman Coulter: J2-21M/E Centrifuge (RRID:SCR_019669) Copy   


https://www.beckman.com/cell-counters-and-analyzers/vi-cell-xr

Cell counter that provides an automatic means to perform the Trypan Blue Dye Exclusion method, allowing users to load up to 9 samples at once for easy and automated cell analysis, and offers pre-programmed and customizable analysis options for consistent and accurate analysis.

Proper citation: Beckman Coulter: Vi-CELL XR Cell Viability Analyzer (RRID:SCR_019664) Copy   


https://www.beckman.com/flow-cytometry/instruments/moflo-xdp

Cell sorter that can perform 70,000 sorts per second and offers a wide variety of sorting applications.

Proper citation: Beckman Coulter: Moflo XDP Cell Sorter Flow Cytometer (RRID:SCR_019665) Copy   


https://www.beckmancoulter.com/wsrportal/techdocs?docname=cyan_adp_instructions_for_use.pdf

Flow cytometer engineered for precision analysis of cells, bacteria, and other similarly sized particles. CyAn ADP utilizes three excitation lines with independent, alignment-free focusing optics, simultaneous nine color and two scatter parameters, analysis rates of 70,000 events per second, a full 9 × 9 inter-laser compensation matrix, and high sensitivity. The instrument is optimized for cell cycle, kinetics, fluorescent protein work, and multi-color immunophenotyping. Rare-event analysis, such as MHC Dextramer studies, and no-lyse whole blood applications are easily performed on the CyAn ADP. The instrument also provides simplified compensation before, during, and after acquisition in all fluorescent parameters.

Proper citation: Beckman Coulter: CyAn ADP High-Speed Analyzer (RRID:SCR_019666) Copy   



Can't find your Tool?

We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.

Can't find the RRID you're searching for? X
  1. RRID Portal Resources

    Welcome to the RRID Resources search. From here you can search through a compilation of resources used by RRID and see how data is organized within our community.

  2. Navigation

    You are currently on the Community Resources tab looking through categories and sources that RRID has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.

  3. Logging in and Registering

    If you have an account on RRID then you can log in from here to get additional features in RRID such as Collections, Saved Searches, and managing Resources.

  4. Searching

    Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:

    1. Use quotes around phrases you want to match exactly
    2. You can manually AND and OR terms to change how we search between words
    3. You can add "-" to terms to make sure no results return with that term in them (ex. Cerebellum -CA1)
    4. You can add "+" to terms to require they be in the data
    5. Using autocomplete specifies which branch of our semantics you with to search and can help refine your search
  5. Save Your Search

    You can save any searches you perform for quick access to later from here.

  6. Query Expansion

    We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.

  7. Collections

    If you are logged into RRID you can add data records to your collections to create custom spreadsheets across multiple sources of data.

  8. Sources

    Here are the sources that were queried against in your search that you can investigate further.

  9. Categories

    Here are the categories present within RRID that you can filter your data on

  10. Subcategories

    Here are the subcategories present within this category that you can filter your data on

  11. Further Questions

    If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.

X