https://www.jeolusa.com/PRODUCTS/Transmission-Electron-Microscopes-TEM/120-kV/JEM-1400Flash
Transmission electron microscope that can be used to first view samples at low magnification before studying fine structures of interest at high magnification.
Proper citation: JEOL: JEOL: JEM-1400Flash Transmission Electron Microscope (RRID:SCR_020179) Copy
https://www.jeolusa.com/PRODUCTS/Nuclear-Magnetic-Resonance/Magnets
Superconducting magnets including actively shielded magnets from 400 to 800 MHz, and ultra high field magnets from 900 to 930 MHz. Magnets feature low cryogen consumption cryostats, extremely small B0 drift characteristics and homogeneity.
Proper citation: JEOL: 400-800 MHz Magnets (RRID:SCR_020152) Copy
J-1500 allows for the maximum flexibility to upgrade your CD system with different measurement techniques. While the standard measurement modes are CD, LD, and absorbance, up to four simultaneous modes can be measured when combined with a wide range of sampling accessories. These accessories can measure a variety of samples, from liquids to films to solid-states. Temperature control systems can be coupled with multi-position cells to run thermal melts, providing researchers with CD and thermodynamic data sets for conformational and folding studies. Automated high-throughput CD can obtain measurements on up to 192 samples without user intervention, saving both time and money. Kinetic and protein dynamics studies can be performed with our dedicated stopped-flow systems that can measure both CD and fluorescence. The wavelength range has also been significantly extended, allowing measurements to be obtained in both the vacuum-UV and NIR spectral regions using the standard PMT detector (163 950 nm) and an optional InGaAs detector (up to 1600 nm). Additional features now allow researchers to optimize their parameter specifications in order to obtain data with the highest resolution and S/N performance for a specific application set.
Proper citation: Jasco: 1500 1500 (RRID:SCR_020147) Copy
https://www.jeolusa.com/PRODUCTS/Sample-Preparation-Tools/Vacuum-Evaporator
High vacuum specimen sample preparation tool. Preparation device that makes it easy to prepare samples for imaging and analysis with with electron microscopes.
Proper citation: JEOL: IB-29500VED/IB-29510VET Vacuum Evaporator Sample Preparation Tool (RRID:SCR_020164) Copy
https://www.jeolusa.com/PRODUCTS/Transmission-Electron-Microscopes-TEM/200-kV/CryoARM-200
Transmission elecctron microscope that achieves unprecedented resolution and stability allowing for automatic and unattended acquisitoin of image data for Single Particle Analysis
Proper citation: JEOL: CRYO ARM 200 Transmission Electron Microscope (RRID:SCR_020161) Copy
https://www.thermofisher.com/order/catalog/product/4485701#/4485701
Applied Biosystems QuantStudio 7 Flex Real-Time PCR System advances your research further by enabling a broad range of real-time PCR-based applications through its multiplexing capabilities and interchangeable block formats. With a simplified workflow, software, automation capabilities, and touch-screen interface, the QuantStudio 7 Flex system offers reproducibility with minimal well-to-well and instrument-to-instrument variation.
Proper citation: Thermo Fisher: Life Technologies: QuantStudio 7 Real Time PCR System (RRID:SCR_020245) Copy
https://www.miltenyibiotec.com/CN-en/products/macsquant-analyzer-16.html
Automated flow cytometer with expanded fluorescence capabilities, enabling measurement of up to 16 parameters.
Proper citation: Miltenyi: Bioscience MACSQuant Analyzer 16 (RRID:SCR_020263) Copy
https://digital.bsd.uchicago.edu/equipment_files/Leica%20SP2%20manual.pdf
Leica TCS SP2 is a spectral confocal laser scanning microscope with 405 UV laser 3CHDIC digital emission 400-800nm range designed to acquire high spatial resolution images of fluorescently labeled materials and for analysis of these images. The confocal principle utilizes a pinhole (confocal aperture) to eliminate out-of-focus light from fluorescently labeled specimens (i.e., provide “optical sectioning�). Lasers provide intense, point illumination that is scanned over the preparation and the fluorescence at each point is quantified and used to construct a representation of the object brightness (an image). This method provides high resolution for the x and y planes as well as vertically (z plane). The SP2 is an advanced confocal system with nine laser excitation lines spanning the spectrum from UV to near IR. The following laser lines are available: 405nm, 458, 476, 488, 496, 514, 543, 594, and 633, all fiber coupled and controlled by AOTFs.
Proper citation: Leica: TCS SP2 Confocal Laser Scanning Microscope (RRID:SCR_020231) Copy
https://www.leica-microsystems.com/products/light-microscopes/p/leica-lmd7000/
Specimen collection by gravity contact-free and contamination-free. Laser Microdissection (LMD) makes it possible to distinguish between relevant and non-relevant cells or tissues. It enables the researcher to obtain homogeneous, ultra-pure samples from heterogeneous starting material. Researcher can selectively and routinely analyze regions of interest down to single cells from all kinds of tissues, even living cells from cell culture, to obtain results that are relevant, reproducible, and specific.
Proper citation: Leica: LMD7000 Laser Microdissection System (RRID:SCR_020232) Copy
https://www.leicabiosystems.com/histology-equipment/microtomes/products/leica-rm2255/
Leica RM2255 rotary microtome is designed for fully motorized sectioning of both paraffin- and the Leica RM2255 in routine and in histology. Its two-in-one design concept, which allows motorized and manual sectioning, provides reproducible high-quality sections.
Proper citation: Leica: RM2255 Automated Microtome (RRID:SCR_020229) Copy
Leica EG1150 H is a heated, paraffin dispensing module with 3-liter capacity and a heated work surface with storage areas for both cassettes and molds. All functions of the EG1150 H are controlled via an easy-to-read LED display, including the temperature settings for left and right hand warming trays, paraffin reservoir, and working surface.
Proper citation: Leica: EG1150H Heated Paraffin Embedding Module (RRID:SCR_020227) Copy
Vibrating blade microtome for sectioning by Leica Biosystems used in neurophysiology, neuropathology, experimental pathology, botany. Fully automated Leica VT1200 S vibrating blade microtome for cutting fresh and fixed tissue in Neuroscience. To achieve sections of the highest quality that retain viable cells on the section surface, the vertical deflection of the blade can be measured by Leica's Vibrocheck measurement device and minimised with the blade holder. The instrument was designed in collaboration with Prof. Dr. Peter Jonas and his group at the Physiology Department, Freiburg Germany.
Proper citation: Leica: VT1200S vibrating microtome (RRID:SCR_020243) Copy
https://www.thermofisher.com/order/catalog/product/A28137#/A28137
System designed for users who need easy-to-use real-time PCR system that doesn't compromise performance and quality. Using OptiFlex technology (featuring 4 coupled channels and white LED) and featuring three independent Veriflex temperature zones, the QuantStudio 3 system enables improved data accuracy and sensitivity for broad range of genomic applications.
Proper citation: Thermo Fisher: Life Technologies: QuantStudio 3 Real Time PCR System (RRID:SCR_020238) Copy
https://www.leica-microsystems.com/products/confocal-microscopes/p/leica-tcs-sp5/
Leica TCS SP5 is a broadband confocal microscope that provides the full range of scan speeds at the a high resolution. With its SP detection (five channels simultaneously) and optional AOBS (Acousto Optical Bream Splitter), the Leica TCS SP5 delivers bright, noise-free images with minimal photo damage at high speed. The system is also the platform for the new Leica DM6000 CFS (Confocal Fixed Stage) for physiological and electrophysiological experiments and for the new super resolution Leica TCS STED confocal microscope.
Proper citation: Leica: TCS SP5 Broadband Confocal Laser Scanning Microscope (RRID:SCR_020233) Copy
https://www.marshallscientific.com/v/vspfiles/files/manuals/User%20Manual%20-%20Gemini%20XS.pdf
SPECTRAmax GEMINI XS Dual-Scanning Microplate Spectrofluorometer can perform a variety of fluorescent applications as well as some time-resolved fluorescent and luminescent assays. The extreme flexibility and high sensitivity of the SPECTRAmax GEMINI XS make it appropriate for applications within the fields of biochemistry, cell biology, immunology, molecular biology, and microbiology. The SPECTRAmax GEMINI XS uses two holographic diffraction grating monochromators which allow for individual optimization of wavelengths for both excitation and emission. The dual-scanning capability can also be used to determine excitation and emission settings for new fluorescent probes. Mirrored optics focus the light into the sample volume and cutoff filters are used to reduce stray light and minimize background interference. The light source is a highpowered Xenon flashlamp; additional flexibility is provided by allowing a variable number of lamp flashes per read. Microplates having 6, 12, 24, 48, 96, and 384 wells can be used in the SPECTRAmax GEMINI XS. Fluorescent detection is achieved from the top, through the entire depth of sample in the microplate well. Detection of species collected on membrane plates is also possible. Two plate carrier adapters are provided with the instrument. The blue adapter is required for optimum performance with standard 96- and 384-well format microplates. The red adapter has been optimized for use with Cliniplate 384 microplates.
Proper citation: Molecular Devices: SpectraMax Gemini XS Microplate Spectrofluorometer (RRID:SCR_020296) Copy
https://www.microscopeinternational.com/product/nikon-smz-1-microscope-on-plain-stand/
Nikon SMZ-1 and SMZ-1B zoom stereo microscopes offer legendary Nikon stereo performance. Developed to fit a variety of applications and OEM needs, these advanced-design stereo microscopes have the features and image quality you expect from Nikon. High-performance optics and a 6V/10W halogen illuminator deliver images with excellent contrast, resolution, and brightness. The SMZ-1 and SMZ-1B are human-engineered to allow long periods of operation without fatigue. Mechanical design is yet rugged for daily trouble-free operation in industrial, laboratory, and classroom environments. All controls are easy to use. Nikon's versatile modular approach allows the SMZ-1/1B to be easily adapted to various configurations such as stand, arm, or table mounting. Similarly, the illuminator can be fixed to the instrument stand, placed in a diascopic base, or attached externally for oblique lighting. The SMZ-1/1B use a Nikon-designed twin-lens objective system inclined at 12o. Only the center of the lenses is used to provide the sharpest three-dimensional image and enable the operator to work more accurately and efficiently for prolonged periods without eye strain.
Proper citation: Nikon: SMZ-1 Microscope (RRID:SCR_020328) Copy
http://www.labwrench.com/?equipment.view/equipmentNo/9411/Nikon/Eclipse-55i/
Versatile Eclipse 55i clinical microscope offers optical capabilities, unsurpassed ergonomic features and is optimized for digital imaging. Its white LED illumination system provides a homogenous and bright distribution of illumination across the field for optimal viewing and digital imaging, resulting in spectacular, vivid, true-to-life colors. ergonomic features, like the stay-in-position stage handle and tilting/telescoping ergonomic eyepiece tube ensure best viewing posture, enabling long hours of observations to be carried out in comfort.
Proper citation: Nikon: 55i Upright Microscope (RRID:SCR_020321) Copy
https://www.labx.com/product/olympus-bh2
Goal of the BH2 was superior optics and customizability, and it soon became very well known for both. Standard equipment on this microscope included 10x widefield high eyepoint eyepieces having a field number of 20, precentered halogen lamps, aspherical collector lenses, and fully enclosed light paths designed to exclude dirt and dust. Auxiliary components for the microscope included photoeyepieces, an automatic exposure photomicrography system, and a wide range of objectives covering the entire range of correction and magnification. In addition, both mechanical and circular stages were offered as were binocular and trinocular observation tubes. Contrast enhancing equipment included phase contrast, differential interference contrast, darkfield, fluorescence, and polarized light.
Proper citation: Olympus: BH-2 Fluorescence Microscope (RRID:SCR_020338) Copy
https://www.marshallscientific.com/Nikon-TMS-Inverted-Phase-Contrast-Microscope-p/ni-tms.htm
Nikon TMS Inverted Phase Contrast Microscope produces high quality images for tissue culture labs, readily meeting biological and metallurgical research needs. This Nikon microscope offers operation with an easy-to-maintain inverted microscope frame. This inverted phase microscope is configured with 4x achromat, 10x Ph1, and 20x Ph2 objectives with critical halogen illumination. The TMS can accommodate a variety of Nikon CF objectives on its revolving triple nosepiece, along with multiple other accessories, such as stage adapters and extenders, sliders and rings, and extra long working condensers. The 4x achromat objective provides a lower magnification for a wider field of view, primarily best for when needing to view a large portion of a slide for study. The 10x Ph1 provides phase contrast low-power magnification, while the 20x Ph2 provides medium-power magnification with a larger aperture.
Proper citation: Nikon: TMS Inverted Phase Contrast Microscope (RRID:SCR_020332) Copy
https://www.barcodesinc.com/motorola/ds4208.htm#
General purpose imager that delivers the speed typical of laser scanners on both 1D and 2D barcodes, accommodating 2D barcodes without sacrificing performance. Users never need to take time to align the barcode with the scanner or pause between scans. Since the DS4208 can scan barcodes printed on paper labels or on mobile phone displays, users can drive revenue by attracting the millions of customers who are using their cell phones to better manage their lives. Retailers can accommodate customers who download mobile coupons, mobile loyalty cards and more. Quick service restaurants can accept mobile coupons at the register. Hotels can allow guests to use electronic loyalty cards stored on their cell phones, eliminating the need to carry physical cards. And since theaters, theme parks and stadiums can scan mobile tickets as easily as a paper ticket, they can offer customers an added convenience: paperless ticketing.
Proper citation: Motorola: DS4208 Barcode Scanner (RRID:SCR_020302) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the RRID Resources search. From here you can search through a compilation of resources used by RRID and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that RRID has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on RRID then you can log in from here to get additional features in RRID such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into RRID you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within RRID that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.