https://www.gmi-inc.com/product/packard-cobra-gamma-counter-series/
Gamma counter available in single, five, or ten detector configurations. Can count RIA tubes, 16x100mm and variety of smaller micro tubes using available adapter.This instrument has dot Matrix Printer, tube racks, and protocol ID tags.Single detector model is available in 2 inch or 3 inch crystal configurations for research grade capabilities.
Proper citation: Packard: Cobra 5000 Gamma Counter (RRID:SCR_018609) Copy
Dual channel fluorimeter for fluorescence measurements when calibrated with known concentration to measure compounds at low concentration with low assay volume.
Proper citation: Promega: TBS-380 Fluorimeter (RRID:SCR_018615) Copy
Microplate luminometer that features two optional injectors and reads both glow- and flash-luminescent reactions in 96-well plates. The sensitivity and range enable a wide range of luminescent assays, including Promega bioluminescent reporter, cell-based and biochemical assays., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Proper citation: Promega: GloMax 96 Microplate Luminometer (RRID:SCR_018614) Copy
Sequencing and quantification platform for epigenetics, mutation gene expression analysis, and microbial identification and resistance typing. With its 96-well format, automatic base-calling function, and dedicated software solutions for methylation analysis and assay design.
Proper citation: Qiagen: PyroMark Q96 System (RRID:SCR_018617) Copy
http://tools.thermofisher.com/content/sfs/brochures/geneatlas_system_brochure.pdf
System for processing Affymetrix microarrays. Microarray analysis system. Includes array strip and hybridization assembly, Fluidics station, Imaging station.
Proper citation: Thermo Fisher: GeneAtlas System (RRID:SCR_018715) Copy
https://www.thermofisher.com/order/catalog/product/ND-8000-GL
Microvolume UV Vis spectrophotometer for nucleic acid and protein quantification that can measure multiple samples using 1 to 2 uL of samples. Can analyze spectrum of 220nm to 750nm and measure 96 samples in less than six minutes. Can measure multiple samples in one measurement cycle, up to eight samples at one time. Has single sample mode. Can analyze the full spectrum from 220 to 750nm and calculates sample purity ratios 260/280.
Proper citation: Thermo Fisher: NanoDrop 8000 Spectrophotometer (RRID:SCR_018600) Copy
https://www.nikonmetrology.com/en-us/product/az100-multizoom
Nikon Instruments AZ100 C1si is macro confocal microscope system combining stereo and compound microscopes into single hybrid imaging system for dynamic imaging of single cells or whole specimens.System covers range of magnifications from 5x to 400x. Has triple nosepiece that can switch magnifications. AZ100 C1si boasts simultaneous 32 channel spectral image acquisition over spectral range of 320 nm in single scan. Simultaneous 32 channel acquisition at 10 nm, 5 nm or 2.5 nm bandwidths, all software controlled, is possible.
Proper citation: Nikon: AZ100 Confocal Microscope (RRID:SCR_018603) Copy
https://www.marshallscientific.com/The-MJ-Research-PTC-100-Thermal-Cycler-p/mj-100.htm
Thermocycler that operates with 96 well and 60 well microplates. Has temperature configurations from 0 C to 105 C and pressure and height adjustment via thumbwheel. Comes with 14 pre-programmed protocols.
Proper citation: Marshall Scientific: MJ Research PTC-100 PCR Thermocycler (RRID:SCR_018602) Copy
https://www.labx.com/product/waters-2695
High performance liquid chromatographic system with quaternary, low pressure mixing pump and inline vacuum degassing. It has wavelengths of 190 to 800 nm and flow rates from 50 uL per min to 5 mL per min with 2.1 mm ID columns and larger. Autosampler has maximum capacity of 120 vials (12x32, 2 mL) with programmable temperature control from 4 to 40C. Heated column compartment provides temperatures from 5 degrees above ambient to 65C.
Proper citation: Waters: 2695 HPLC System (RRID:SCR_018649) Copy
http://labx.com/product/stratagene-stratalinker-1800
UV crosslinker designed to crosslink DNA or RNA to nylon, nitrocellulose, or nylon reinforced nitrocellulose membranes in 25 to 50 seconds. It is equipped with internal photodetector to compensate for aging ultraviolet bulbs.
Proper citation: Stratagene: 1800 UV Crosslinker (RRID:SCR_018631) Copy
https://www.labx.com/product/sciex-4000-qtrap-
Hybrid triple quadrupole linear ion trap mass spectrometer for drug discovery and development, metabolite identification, contaminant testing, proteomic applications, post translationally modified proteins discovery, protein identification, and biomarker validation.
Proper citation: SCIEX: 4000 QTRAP Mass Spectrometer (RRID:SCR_018630) Copy
https://www.tainstruments.com/3200-system/
Mechanical testing apparatus with 225 N or 450 N maximum force and range of static to 300 Hz frequency response. Tests include torsion testing, creep under dynamic loading, special environment hot cold chambers, biomedical research, and engineered materials test applications..
Proper citation: TA Instruments: Electroforce 3200 Mechanical Testing Apparatus (RRID:SCR_018637) Copy
Automated wide range incubator used to minimize plate movement, receive samples, store plates, and track plates.Temperature range is from 10 to 50 degrees Celsius with humidity level of up to 95 rH.
Proper citation: Thermo Fisher: Cytomat 6001 Automated Wide Range Incubator (RRID:SCR_018646) Copy
Ultracentrifuge is used for centrifugation of subcellular particles, virus isolations, and high purity plasmid DNA.
Proper citation: Beckman Coulter: L-90K Ultracentrifuge (RRID:SCR_019651) Copy
https://www.brookhaveninstruments.com/product/bi-200sm-research-goniometer/
Goniometer that is used for macro molecular studies and submicron particle sizing with static and dynamic light scattering. It can be used with neutral density filters, polarizer, analyzer, and reference detector.
Proper citation: Brookhaven Instruments: BI-200SM Research Goniometer (RRID:SCR_019754) Copy
Benchtop genetic analyzer. Electrophoresis system for DNA and RNA sample quality control. It can be used for next generation sequencing or Biobank workflow.
Proper citation: Agilent: 4200 TapeStation System (RRID:SCR_018435) Copy
http://tools.thermofisher.com/content/sfs/manuals/cms_040970.pdf
Automated PCR instrument for automated amplification of nucleic acids with Polymerase Chain Reaction. It has reaction volumes of up to 50 uL and sample temperature range of 4 to 99.9 C.
Proper citation: Thermo Fisher: Applied Biosystems: GeneAmp 9700 PCR Thermocycler System (RRID:SCR_018436) Copy
Provides services for USED lab instrument repairs.Recertified laboratory equipment commercially available. Comes fully re-certified to manufacturers standards with 90 day warranty.
Proper citation: Certified Genetool, Inc. (RRID:SCR_018678) Copy
https://www.research.chop.edu/flow-cytometry
Core provides access to instrumentation and technical expertise. Offers services, including sample preparation, advanced multi-color analysis, and high-speed cell sorting. Our experienced staff delivers personalized training and project-specific consultations.
Proper citation: Children's Hospital of Philadelphia Flow Cytometry Core Facility (RRID:SCR_009726) Copy
Core offers services for genomic next-generation sequencing library preparation, sequencing and analysis applications including RNAseq, ChIPseq, ATACseq, CRISPR screening, whole genome methylation profiling, targeted resequencing, single-cell RNAseq, exome sequencing, and more. Performs bioinformatics analysis such as integration of multi-omics datasets or specialized analyses. Genomics core technology platforms include Illumina NovaSeq6000, NextSeq500s, MiSeqs, MiniSeq. High throughput sample preparation is performed on Beckman Coulter Biomek FX and i7 systems. Low throughput samples are prepared by technical staff.
Proper citation: Dana-Farber Cancer Institute Molecular Biology Core Facility (RRID:SCR_009754) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the RRID Resources search. From here you can search through a compilation of resources used by RRID and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that RRID has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on RRID then you can log in from here to get additional features in RRID such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into RRID you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within RRID that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.