Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
| Resource Name | Proper Citation | Abbreviations | Resource Type |
Description |
Keywords | Resource Relationships | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Oxford: Nanopore Technologies MinION Resource Report Resource Website 100+ mentions |
Oxford: Nanopore Technologies MinION (RRID:SCR_017985) | instrument resource | Portable, real time device for DNA and RNA sequencing, putting you in control of your sequence data. Portable DNA/RNA sequencing by Oxford Nanopore Technologies. | sequencing machine, hardware, high-throughput sequencing, instrument, equipment |
is related to: NanoporeTech: GridION Mk1 is related to: Oxford: Nanopore Technologies: PromethION |
Restricted | https://nanoporetech.com/sites/default/files/s3/literature/MinION-Mk1C-brochure.pdf | SCR_017985 | 2026-08-01 12:06:09 | 107 | |||||||||
|
Molecular Devices: Molecular Dynamics Storm 840 Molecular Imager Resource Report Resource Website |
Molecular Devices: Molecular Dynamics Storm 840 Molecular Imager (RRID:SCR_018031) | instrument resource | Molecular imager system for performing gel and blot analysis. This system provides both PhosphorImager capabilities along with non-radioactive fluorescent labeling techniques-direct fluorescence and chemifluorescence. It can be used for non-radioactive gel and blot analysis methods or radioisotope techniques. Storm 840 scans storage phosphor screens plus fluorescent gels and chemifluorescent blots in the 35 x 43 cm scanning area. | ABRF, molecular imager, GE HealthCare, gel, blot, macromolecular analysis, instrument, equipment | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018031.pdf | Model_Number_840 | https://btiscience.org/wp-content/uploads/2014/04/Storm_User_Manual.pdf | https://www.mbl.edu/jbpc/files/2014/05/Storm_Info.pdf | SCR_018031 | Storm Gel and Blot Imaging System, Storm 840 Molecular Imager, Molecular Dynamics Storm 840 Phosphorimager Scanner | 2026-08-01 12:06:17 | 0 | ||||||
|
AGFA: CP1000 Automatic Film Processor Resource Report Resource Website |
AGFA: CP1000 Automatic Film Processor (RRID:SCR_018030) | instrument resource | THIS RESOURCE IS NO LONGER IN SERVICE. Documented on April 10,2024. Automatic film processor for low-volume processing or back-up purposes. Its features include fast start up (7 minutes from cold start) and 125-second cycle time. Uses simple, accessible film transport system with fewer rollers than conventional heavy roller racks, infrared dryer instead of hot-air dryer, 400 watts of power when in operation and 100 watts in standby mode, and automatic temperature control and drying. | ABRF, film developer, film processor, instrument, equipment | is listed by: USEDit | THIS RESOURCE IS NO LONGER IN SERVICE | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018030.pdf | Model_Number_AGFA_CP1000 | https://www.service-power.at/wp-content/uploads/2014/04/Agfa-CP-1000_EN.pdf | SCR_018030 | AGFA CP1000 Film Developer | 2026-08-01 12:06:09 | 0 | ||||||
|
Thermo Fisher: Affymetrix: GeneChip 450 Fluidics Station Microarray Processer Resource Report Resource Website 10+ mentions |
Thermo Fisher: Affymetrix: GeneChip 450 Fluidics Station Microarray Processer (RRID:SCR_018034) | instrument resource | Microarray processor that washes and stains GeneChip arrays.110V and 220V compatible. | ABRF, fluidics station, instrument, equipment | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018034.pdf | Model_Number_450 | https://assets.thermofisher.com/TFS-Assets/LSG/manuals/fs450_agcc_user_guide.pdf | SCR_018034 | GeneChip Fluidics Station 450, GeneChip 450 Fluidics station | 2026-08-01 12:06:09 | 18 | |||||||
|
Molecular Devices: GenePix 4000B Microarray Scanner Resource Report Resource Website 1+ mentions |
Molecular Devices: GenePix 4000B Microarray Scanner (RRID:SCR_018049) | instrument resource | Microarray scanner that performs genetic and compound analysis. Coupled with GenePix ProMicroarray Image Analysis Software and Acuity Microarray Informatics Software for acquisition and analysis of data from all types of arrays, including nucleic acids, proteins, tissues, and cells. Scanner flexibility allows to configure scanning and analysis of one slide or many, whether they are all alike or each is different. Slide loader accommodates low- and high-density, opaque, mirrored, or translucent, plastic or glass, commercial or homebrew slides. | ABRF, scanner, microarray scanner, instrument, equipment | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018049.pdf | SCR_019955, Model_Number_4000B | https://www.moleculardevices.com/sites/default/files/en/assets/data-sheets/br/genepix-4000b-microarray-scanner.pdf | SCR_018049 | GenePix 4000B Scanner | 2026-08-01 12:06:10 | 1 | |||||||
|
Thermo Fisher: NanoDrop 2000 Spectrophotometer Resource Report Resource Website 50+ mentions |
Thermo Fisher: NanoDrop 2000 Spectrophotometer (RRID:SCR_018042) | instrument resource | Full-spectrum, UV-Vis spectrophotometer used to quantify and assess purity of DNA, RNA, Protein and more. The NanoDrop 2000 is microvolume spectrophotometer with patented sample retention technology that measure sample volumes as small as 0.5L. | ABRF, spectrophotometer, nanodrop 2000, microvolume sample measurement, instrument, equipment |
is listed by: USEDit is related to: Thermo Fisher: NanoDrop 2000c Spectrophotometer is related to: Thermo Fisher: NanoDrop Lite Spectrophotometer |
https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018042.pdf | Model_Number_ND_2000 | https://assets.thermofisher.com/TFS-Assets/CAD/Specification-Sheets/D17050~.pdf | SCR_018042 | , NanoDrop 2000, NanoDrop 2000 Spectrophotometer | 2026-08-01 12:06:10 | 73 | |||||||
|
Prayoga: GenapSys Sequencer Resource Report Resource Website 10+ mentions |
Prayoga: GenapSys Sequencer (RRID:SCR_017991) | instrument resource | Compact sequencer for DNA sequencing by GenapSys, Inc. Sequencing is carried out on microfluidic chips that have scalable number of detectors, allowing for applications ranging from targeted sequencing of specific amplicons to genome-scale data collection. System utilizes electrical sequencing chip., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025. | sequencing machine, hardware, high-throughput sequencing, instrument, equipment | DOI:10.1101/604553 | THIS RESOURCE IS NO LONGER IN SERVICE | https://www.sopachem.com/lifesciences/wp-content/uploads/2020/04/GenapSys-Sequencer-Specification-Sheet.pdf | https://www.genapsys.com/products/ | SCR_017991 | 2026-08-01 12:06:09 | 14 | ||||||||
|
PacBio: Sequel II System Resource Report Resource Website 50+ mentions |
PacBio: Sequel II System (RRID:SCR_017990) | instrument resource | Sequencer by Pacific Biosciencies. System provides advantages of SMRT Sequencing and now makes it more affordable for all scientists to drive discovery with comprehensive views of genomes and transcriptomes. Generates 8 times more data than original Sequel System. Provides access to highly accurate long reads (HiFi reads). Reduces project time for faster results. Makes sequencing more affordable.Supports range of SMRT Sequencing applications. | sequencing machine, hardware, high-throughput sequencing, instrument, equipment | Restricted | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_017990.pdf | https://www.pacb.com/wp-content/uploads/Operations-Guide-Sequel-II-and-Sequel-IIe-Systems.pdf | https://www.pacb.com/products-and-services/sequel-system/latest-system-release/ | SCR_017990 | 2026-08-01 12:05:53 | 54 | ||||||||
|
Thermo Fisher: Applied Biosystems: 2720 Thermal Cycler Resource Report Resource Website 1+ mentions |
Thermo Fisher: Applied Biosystems: 2720 Thermal Cycler (RRID:SCR_018045) | instrument resource | Personal sized 96-well thermal cycler that performs both basic PCR and cycle-sequencing applications using 0.2 mL reaction tubes or 96-well reaction plates. Its dimensions are 21 cm (8.3 in.) wide and 36 cm (14.2 in.) deep with cooling vents. | ABRF, Thermal Cycler, PCR, cycle sequencing, Applied Biosystems, instrument, equipment | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018045.pdf | Model_Number_2720 | https://assets.thermofisher.com/TFS-Assets/LSG/manuals/cms_041483.pdf | SCR_018045 | ABI 2720 Thermal Cycler | 2026-08-01 12:06:10 | 4 | |||||||
|
Roche: 454 GS FLX Genome Sequencer Resource Report Resource Website 1+ mentions |
Roche: 454 GS FLX Genome Sequencer (RRID:SCR_018028) | instrument resource | Genetic sequencer that sequences clinically relevant exons and identifies genomic variations in solid tumors treated with antibody-based medicine. Scaled version of Genome Sequencer FLX System for use by individual labs. Features include simple sample preparation workflow, overnight sequencing and data processing, and suite of data analysis software. | ABRF, genetic sequencer, DNA sequencing, data processing, data analysis, instrument, equipment | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018028.pdf | Model_Number_454 | https://dna.cs.byu.edu/bio465/454/Genome%20Sequencer%20FLX%20Operator's%20Manual_LowRes.pdf | SCR_018028 | Roche 454 GS FLX, 454 GS FLX | 2026-08-01 12:05:53 | 1 | |||||||
|
Bio-Rad: Bio-Plex 200 System Resource Report Resource Website 100+ mentions |
Bio-Rad: Bio-Plex 200 System (RRID:SCR_018026) | instrument resource | Suspension array system which offers protein and nucleic acid researchers multiplex assay solution permiting analysis of up to 100 biomolecules in single sample. | ABRF, suspension array reader, protein, nucleid acid, assay, analysis, instrument, equipment, Bio-Rad | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018026.pdf | https://rai.unam.mx/manuales/umyp_Manual_Bioplex.pdf | SCR_018026 | , Bio-Plex 200 System, Bio-Plex 200 Suspension Array System, BioRad suspension array reader | 2026-08-01 12:06:17 | 151 | ||||||||
|
Luminex: 100 Flow Cytometry Analyzer System Resource Report Resource Website 10+ mentions |
Luminex: 100 Flow Cytometry Analyzer System (RRID:SCR_018025) | instrument resource | Flow cytometry analyzer system for individual labs that performs up to 100 different tests in single reaction volume and can use either magnetic beads or plain polystyrene beads. | ABRF, suspension array analyzer, flow cytometry, magnetic bead, polystyrene bead, analysis, Luminex Corporation, instrument, equipment |
is listed by: USEDit is related to: Thermo Fisher: Luminex 200 Instrument System |
https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018025.pdf | https://www.luminexcorp.com/research-luminex-100200/ | SCR_018025 | Luminex 100 System | 2026-08-01 12:06:09 | 17 | ||||||||
|
Illumina: HiSeq 1500 System Resource Report Resource Website 1+ mentions |
Illumina: HiSeq 1500 System (RRID:SCR_018006) | instrument resource | High-throughput sequencing system. Support of instrument and supply reagents will be provided through February 28th, 2023. Other instruments that support same applications as HiSeq 1500 System are available. Use Sequencing Platform Comparison Tool to find the best instrument for your needs. | Illumina, genomic, hardware, instrument, equipment, sequencer, sequencing | Restricted | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018006.pdf | https://support.illumina.com/content/dam/illumina-support/documents/documentation/system_documentation/hiseq1500/hiseq-1500-system-guide-15035788-03.pdf | SCR_018006 | HiSeq 1500 System | 2026-08-01 12:06:16 | 1 | ||||||||
|
Thermo Fisher: Applied Biosystems: 7900HT Fast Real-Time PCR System Resource Report Resource Website 10+ mentions |
Thermo Fisher: Applied Biosystems: 7900HT Fast Real-Time PCR System (RRID:SCR_018060) | instrument resource | Real Time quantitative PCR system that combines 96- and 384-well plate compatibility and the TaqMan Low Density Array with fully automated robotic loading and now also offers optional Fast real-time PCR capability. High-throughput Real-Time PCR system that detects and quantitates nucleic acid sequences. Uses fluorescent-based PCR chemistries to provide: Quantitative detection of nucleic acid sequences using real-time analysis and Qualitative detection of nucleic acid sequences using end-point and dissociation-curve analysis. | ABRF, PCR, Real-Time PCR System, Fast 96-Well Block Module, instrument, equipment | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018060.pdf | Model_Number_7900HT | https://assets.fishersci.com/TFS-Assets/LSG/manuals/cms_039844.pdf | SCR_018060 | Applied Biosystems 7900HT PCR System | 2026-08-01 12:05:54 | 15 | |||||||
|
Leica: CM1950 Cryostat Resource Report Resource Website 10+ mentions |
Leica: CM1950 Cryostat (RRID:SCR_018061) | instrument resource | Highly adaptable cryostat platform that can be tailor-made for each laboratory. Cryostat with encapsulated microtome and separate specimen cooling features UV disinfection system, optional integrated extraction system for section waste and optional motor for motorized sectioning. Designed to produce frozen sections for biological, medical and industrial applications. | ABRF, Cryostat, Leica, instrument, equipment | THIS RESOURCE IS NO LONGER IN SERVICE | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018061.pdf | Model_Number_CM1950 | https://drp8p5tqcb2p5.cloudfront.net/fileadmin/downloads_lbs/Leica%20CM1950/User%20Manuals/Leica_CM1950_IFU_2v1N_en.pdf | SCR_018061 | CM1950 Cryostat | 2026-08-01 12:06:17 | 35 | |||||||
|
Sony Biotechnology Inc. SP6800 Spectral Cell Analyzer Resource Report Resource Website 10+ mentions |
Sony Biotechnology Inc. SP6800 Spectral Cell Analyzer (RRID:SCR_018067) | instrument resource | Analyzer that uses spectral technology to collect photons from 420nm to 800nm. Global standardization mode automatically sets system to master specification with single click. Sony patented Flowpoint core stability and tracking system and automated QC ensure highest resolution possible of target populations. | ABRF, Spectral Analyzer, instrument, equipment, Sony Biotechnology | is listed by: USEDit | Model_Number_SP6800 | https://www.sonybiotechnology.com/wordpress/wp-content/uploads/2017/08/SP6800-2017-web-073017.pdf | SCR_018067 | 1 SP6800 cell analyzer | 2026-08-01 12:06:17 | 10 | ||||||||
|
Bio-Rad: iCycle iQ Real-Time Detection System Resource Report Resource Website 1+ mentions |
Bio-Rad: iCycle iQ Real-Time Detection System (RRID:SCR_018065) | instrument resource | PCR detection system that features broad spectrum light source. Filter based optical design allows selection of optimal wavelengths of light for excitation and emission. Pixel array on CCD detector allows for simultaneous imaging of all 96 wells every second. Simultaneous image collection insures that well-to-well data may reliably be compared. Reports data on PCR in progress in Real Time, allowing immediate feedback on reaction success. | ABRF, Thermal Cycler, RT PCR, instrument, equipment, Bio Rad | is listed by: USEDit | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018065.pdf | Model_Number_iCycle | https://www.bio-rad.com/webroot/web/pdf/lsr/literature/4006200E.pdf | SCR_018065 | Bio-Rad iCycle Thermal Cycler | 2026-08-01 12:05:54 | 2 | |||||||
|
Parker: Picospritzer III Resource Report Resource Website 1+ mentions |
Parker: Picospritzer III (RRID:SCR_018152) | instrument resource | Intracellular microinjection dispense system by Parker Hannifin. Supplies repeatable pressure pulses. Designed for rapid and reproducible ejections of picoliter and nanoliter volumes used in conjunction with intracellular or extracellular studies while avoiding inherent desensitization of nerve cells which accompanies Iontophoretic methodology. System comes complete with high speed valves and necessary tubing assemblies. | Intracellular microinjection, dispense system, Parker Hannifin, pressure pulse, ejection picoliter volume, nanoliter volume, desensitization of nerve cell, instrument, equipment | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018152.pdf | https://www.parker.com/content/dam/Parker-com/Literature/Literature-Files/pneutronics/Catalogs/Picospritzer.pdf | SCR_018152 | Picospritzer III - Intracellular Microinjection Dispense Systems | 2026-08-01 12:05:55 | 5 | |||||||||
|
Dolomite Bio: Nadia High Throughput Cell Analyzer Platform Resource Report Resource Website |
Dolomite Bio: Nadia High Throughput Cell Analyzer Platform (RRID:SCR_018154) | instrument resource | Automated, microfluidic droplet based platform for single cell research that encapsulates up to 8 samples. Instrument has sample temperature control from 4 degrees Celsius to 40 degrees Celsius. System detects single use cartridges for specific applications. | Dolomite Bio, high throughput cell processing, microfluidic droplet, single cell, Nadia instrument, instrument, equipment | Restricted | https://www.labunlimited.co.uk/pdf/Nadia%20scRNA-Seq%20application%20note.pdf | SCR_018154 | Nadia Instrument | 2026-08-01 12:06:18 | 0 | |||||||||
|
TDT: RZ6 Multi-I/O Processor Resource Report Resource Website 1+ mentions |
TDT: RZ6 Multi-I/O Processor (RRID:SCR_018153) | instrument resource | Processor for auditory research delivers processing power, data transfer and sample rate of 200 kHz by Tucker-Davis Technologies . Can be equipped with up to 4 high-performance DSPs to support complex stimulus control, high frequency applications, and real time normalization for speakers and microphones. | Processor, auditory research, stimulus control, high frequency application, real time normalization, speaker, microphone, Tucker-Davis Technologies, instrument, equipment | Restricted | https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/main/PDF/SCR_018153.pdf | https://www.tdt.com/files/manuals/hardware/RZ6.pdf | SCR_018153 | 2026-08-01 12:06:11 | 5 |
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the RRID Resources search. From here you can search through a compilation of resources used by RRID and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that RRID has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on RRID then you can log in from here to get additional features in RRID such as Collections, Saved Searches, and managing Resources.