Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
https://www.bdbiosciences.com/documents/FACSCalibur_FlowCytometry_TechSpec.pdf
Automated benchtop flow cytometry system. It allows measuring four fluorochrome-conjugates, forward and side scatter., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Proper citation: BD Biosciences: FACSCalibur Flow Cytometry System (RRID:SCR_000401) Copy
https://biospherix.com/oxycycler-gt4181n/
Nitric Oxide, O2, CO2 controller with limit control of relative humidity and monitoring of temperature conditions when used in combination with C-Chamber incubator subchamber from BioSpherix. Features secondary monitor of Nitric Oxide and may be used in combination with I-Hood Incubator Hood from BioSpherix in order to ventilate fumes.
Proper citation: BioSpherix: Oxycycler GT4181N Controller (RRID:SCR_021112) Copy
https://www.coolled.com/products/pe-300white/
Compact and simple to use LED illuminator for microscopes. Provides broad spectrum of illumination, covering excitation bands of fluorophores such as DAPI, CFP, Aqua, FITC, TRITC, TxRed, Cy5 and many more. Operation is by manual control pod with instant on and off, irradiance control, with remote control available via USB or TTL trigger.
Proper citation: CoolLED: pE-300white (RRID:SCR_021073) Copy
https://biospherix.com/i-hood/
Protective hood for removing fumes which may escape incubator.
Proper citation: BioSpherix: I-Hood Protective Incubator Hood (RRID:SCR_021108) Copy
https://www.neurasmus.nl/index.php/products/blink-2-0
Scientific setup used for both eyeblink conditioning and prepulse inhibition of startle reflex in animals. Used to measure kinetic and frequency domain properties of conditioned and unconditioned eyelid responses in freely moving mice. Allows determination of eyelid movements in time and space while using air puff as unconditioned stimulus.
Proper citation: Neurasmus: BLINK system (RRID:SCR_021043) Copy
https://mdc.custhelp.com/euf/assets/content/Digidata_1322A_Manual.pdf
Digitizer intended for precision scientific applications.Digitizes at aggregate speed of 500 kHz. It provides sixteen multiplexed, 16-bit analog inputs and two nonmultiplexed, 16-bit analog outputs.
Proper citation: Molecular Devices: Digidata 1322A Digitizer (RRID:SCR_021041) Copy
https://neurophysics.ucsd.edu/Manuals/Axon%20Instruments/Digidata_1440A_Manual.pdf
Digitizer for electrophysiology experiments, to send and receive signals from microelectrode amplifiers, and to interact with peripheral instruments such as solution changers and stimulators. High resolution, low noise digitizer intended for precision scientific applications. Digidata 1440A digitizer communicates with the host computer using USB 2.0. It is plug and play device, so it is automatically recognized by Windows.
Proper citation: Molecular Devices: DigiData 1440 digitizer (RRID:SCR_021038) Copy
MEA amplifier for upright microscopes.Raw data from up to 60 electrodes of microelectrode array is amplified by 60 channels of filter amplifiers that are built very small and compact using Surface Mounted Devices technology.
Proper citation: Multichannel Systems: MEA60 Amplifier (RRID:SCR_021039) Copy
https://www.kloe-france.com/en/laser-lithography/photolithography-systems/uv-exposure/uv-kub-2
Compact exposure masking system is UV-LED masking system equipped with LED based optical head, collimated and homogeneous.One level mask aligner. Its masking function enables to reach resolutions less than 1um. This system is compatible with any of photoresists such as AZ series, Shipley series, SU-8 and K-CL series.
Proper citation: Kloe: UV-KUB 2 - UV-LED masking system (RRID:SCR_021141) Copy
https://andor.oxinst.com/products/scmos-camera-series/zyla-5-5-scmos
Large field of view, high resolution 5.5 megapixel sCMOS camera, ideal for research and OEM usage. Zyla 5.5 offers 100 fps frame rate and ultra low noise performance, in compact design.USB 3.0 version is available, offering up to 40 fps and industry fastest ROI speeds.
Proper citation: Andor: Zyla 5.5 sCMOS (RRID:SCR_021136) Copy
https://biospherix.com/i-glove/
Oxygen controlled Glovebox for both incubation and handling of cells in controlled physiologic or pathophysiologic conditions when used together with third party incubator. Carbon dioxide control is optional. Hosts C-Chamber Incubator Subchamber for transport of cells without exposure to room air.
Proper citation: BioSpherix: I Glove Incubator and Oxygen Glovebox chamber (RRID:SCR_021083) Copy
https://raw.githubusercontent.com/SciCrunch/RRID-Instruments/refs/heads/main/PDF/SCR_021097.pdf
Thermocycles with added control of VeriFlex technology, with six independent temperature blocks that provide precise control over PCR optimization. Color touch screen simplifies setup and use. Optional setups for fast or standard PCR methods provide with flexibility to shorten your PCR cycling times. Equipped with astandard 0.2 mL block configuration.Will be discontinued on December 31, 2021.
Proper citation: Thermo Fisher: Applied Biosystems: Veriti 96-Well Thermal Cycler (RRID:SCR_021097) Copy
http://pharmaspb.com/system/product/catalog_file/INCellAnalyzer2000/GE%20INCellAnalyzer2000.pdf
Cell imaging system for entire high content analysis (HCA) workflow. Delivers high performance hardware, software, and expert support for cell analysis.
Proper citation: GE: IN Cell Analyzer 2000 cell imaging system (RRID:SCR_021128) Copy
https://www.coolled.com/products/pt-100/#description
LED illumination system for transmitted light applications, including brightfield, darkfield, DIC, Dodt gradient contrast and phase contrast. Includes LED illuminator and controller.
Proper citation: CoolLED: pT-100 (RRID:SCR_021316) Copy
https://biospherix.com/oxystreamer/
Controller for live cell microscopy provides two identical streams of any mix of oxygen and carbon dioxide gas without use of premixed gas cylinders. Eliminates need for pre-mixed gas. Controller is used primarily to pre-condition perfusion media while simultaneously conditioning headspace above culture.
Proper citation: BioSpherix: OxyStreamer Controller (RRID:SCR_021176) Copy
https://www.3dhistech.com/research/tissue-microarrayers/tma-grand-master/
Automated tissue microarrayer, allowing precise selection and extraction of specific regions of interest on donor blocks and their insertion in recipient blocks.Controlled by TMA Control software.
Proper citation: 3DHISTECH: TMA Grand Master (RRID:SCR_021257) Copy
Carl Zeiss Stemi DV4 series stereomicroscope.
Proper citation: Zeiss: Stemi DV4 Stereomicroscope (RRID:SCR_021244) Copy
https://www.zeiss.com/microscopy/us/products/light-microscopes/axio-observer-for-biology.html
Microscope with inverse platform for multimodal imaging of living and fixed specimens. Open and flexible inverted microscope platform with AI assisted experiment startup., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Proper citation: Zeiss: Axio Observer (RRID:SCR_021351) Copy
Research Transmission Electron Microscope with accelerating voltage of 80kV used to image low contrast biological samples.
Proper citation: Zeiss: Electron Microscope 900 (RRID:SCR_021364) Copy
https://drive.google.com/drive/folders/136wOxUgQKWqsesWFTmnvWh2QTJyfi-v5
Research transmission electron microscope with accelerating voltage of 80-200kV. Transmission Electron Microscope from FEI (now Thermo Fisher Scientific) is equipped with LaB6 cathode. Enables both bright field EM and scanning transmission electron microscopy (STEM) at very high resolution (at 200kV: point resolution up to 0.27 nm).
Proper citation: Tecnai G2 20 Electron Microscope (RRID:SCR_021365) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the RRID Resources search. From here you can search through a compilation of resources used by RRID and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that RRID has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on RRID then you can log in from here to get additional features in RRID such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into RRID you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within RRID that you can filter your data on
Here are the subcategories present within this category that you can filter your data on